Alert Rule Builder & Alarm History

Rule: tag, condition, priority, recipients, escalation • History table with ack times

Create Alert Rule

Shift Operators Plant Manager
to

Alarm History (Last 7 Days)

Time Priority Tag Description Value Limit Acknowledged Closed Ack By Dur.
18 Nov, 07:14:22CriticalA-301.H2S_OUTH₂S Scrubber Outlet High52 ppm> 50 ppm07:15:10—Ravi Sharma48s
18 Nov, 06:30:00HighD-2.TEMPDigester D-2 Temp Low37.8°C< 38.0°C06:32:1507:10:00Rajesh Kumar38m
17 Nov, 22:10:05HighCAM-07Camera Feed LostNo Data> 30s22:12:30—IT - Patel2m
17 Nov, 14:22:10CriticalC-203.STATUSCompressor C-203 TripSTOPPEDRUNNING14:25:00—Amit Singh3m
17 Nov, 11:08:55WarningD-2.FOAMDigester D-2 Foam High28%> 25%11:10:2211:45:00Rajesh Kumar35m
16 Nov, 18:45:10HighUPG.CH4_OUTProduct CH₄ Below Spec94.2%> 95%18:48:0019:30:00Ravi Sharma42m
16 Nov, 09:15:40WarningM-311Off-gas Meter Drift+6.2%> 5%09:18:0010:00:00Auto (Value Normal)42m
15 Nov, 23:10:22CriticalC-201.DISCHARGE_PCompressor Discharge High262 bar> 260 bar23:11:0023:15:00Rajesh Kumar4m
15 Nov, 16:30:00HighGH.LEVELGas Holder Level High92%> 90%16:32:0017:00:00Ravi Sharma28m
14 Nov, 19:55:40HighD-1.PHDigester D-1 pH High7.85> 7.819:58:0020:30:00Rajesh Kumar32m
14 Nov, 11:20:15CriticalGAS_LEAK.COMPCompressor House CH₄ Leak28% LEL> 20% LEL11:21:0011:45:00Safety - Singh24m
14 Nov, 08:45:33WarningD-2.LEVELDigester D-2 Level Low78%< 80%08:48:0009:30:00Rajesh Kumar42m
Showing 12 of 147 alarms (7 Critical, 28 High, 52 Warning, 60 Info)
Avg Ack Time (Critical)
2 min 15s
Target: < 5 min
Avg Ack Time (High)
18 min 30s
Target: < 15 min
Alarms per Shift (Avg)
4.2
Down from 6.1 last month
Auto-Resolved %
23%
Return-to-normal auto-ack

Configured Alert Rules (42 Active)

Rule NameTagConditionPriorityRecipientsEscalationStatusActions
H₂S Scrubber Outlet HighA-301.H2S_OUT> 50 ppmCriticalShift Ops, Plant Mgr, Safety15 min → SafetyActive
Digester Temp LowD-*.TEMP< 38.0°CHighShift Ops, Plant Mgr30 min → Plant MgrActive
Digester Temp HighD-*.TEMP> 40.0°CCriticalShift Ops, Plant Mgr, Safety5 min → SafetyActive
Gas Holder Level HighGH.LEVEL> 90%HighShift Ops30 min → Plant MgrActive
Compressor Discharge HighC-*.DISCHARGE_P> 260 barCriticalShift Ops, Maint5 min → Maint LeadActive
Product CH₄ Below SpecUPG.CH4_OUT< 95%HighShift Ops, Plant Mgr15 min → Plant MgrActive
Camera Feed LostCAM-*.HEARTBEATNo data > 30sHighIT, Safety30 min → IT LeadActive
Compressor TripC-*.STATUS= STOPPED (unexpected)CriticalShift Ops, Maint, Plant Mgr5 min → Maint LeadActive
Gas Leak DetectionGAS_LEAK.*> 20% LELCriticalAll On-Site, Safety, Plant MgrImmediate → AllActive
Digester pH Out of RangeD-*.PH< 6.8 or > 7.8HighShift Ops, Plant Mgr15 min → Plant MgrActive